About Fine Bubble Diffuser
Owing to our rich industrial experience, we have been a prominent manufacturer of Fine Bubble Diffuser to our widely scattered clients. This diffuser is used for fine bubble diffused aeration. It is sturdily constructed using high quality raw materials and have a long lifespan. Coming with easy and fast installation features, our Fine Bubble Diffuser is highly demanded in national as well as international markets. We offer it at cost- effective prices in the market among that of our competitors.
Features:
- Increases capacity of clarifier
- Enhances particle agglomeration and growth
- Enhances suspended solids concentration
- Installation is fast and easy
Specifications
| Type | Membrane OD | Length | Air Flow Rate |
| PPA-63-610 | 63 mm | 610 mm | 2.0 - 7.0 m3/hr |
| PPA-63-1000 | 63 mm | 1000 mm | 7.0- 1/2 10.0 m3/hr |
| PPA-90-1000 | 90 mm | 1000 mm | 9.0- 1/2 12.5 m3/hr |
Product Details:
| Minimum Order Quantity | 1 Unit |
| Effective Area of Membrane | 0.1 sqm. |
| Size of Bubbles | 1.0 to 2.0 mm |
| MOC of End Cap | PVC |
| Operating Temperature Range | 35 - 85 Deg C |
| Material | EPDM/ Silicon |
| Length | 610 mm |
| Size of End Connection | 3/4" NPT |
| Model | EWS-63-610 |
| Diameter | 63 mm |
| Air flow Rate | 2.0 - 7.0 cum/hr |
Consistent Fine Bubble AerationDesigned to generate bubbles with diameters between 1 mm and 3 mm, this diffuser maximizes oxygen transfer and mixing efficiency in biological wastewater and aeration tanks. Fine bubbles improve oxygen dissolution rates, promoting effective microbial activity crucial for treatment processes.
Versatile Installation & MaterialsThe diffuser is compatible with 3/4 inch BSP/NPT threaded connections, allowing easy installation in both horizontal and vertical submerged setups. Built with durable materials such as EPDM, silicone, polyurethane, ABS, and PVC, it withstands rigorous environments and offers a service life of 58 years.
Low Maintenance & Energy EfficientRequiring no intrinsic power, this diffuser operates efficiently when connected to a compressor or air blower. Its low pressure drop (15003500 Pa) minimizes energy consumption, while the robust membrane ensures prolonged performance and reliability in demanding applications.
FAQs of Fine Bubble Diffuser:
Q: How should the Fine Bubble Diffuser be installed for optimal performance?
A: The diffuser can be mounted either horizontally or vertically while fully submerged in the tank. Use the 3/4 inch BSP or NPT male threaded connector for secure attachment. Ensure even air distribution and submersion depth for consistent aeration.
Q: What is the recommended air flow rate for the 9-inch diffuser model?
A: For the standard 9-inch membrane diffuser, an air flow range of 1 to 6 cubic meters per hour (m/hr) is recommended. This ensures the best balance of oxygen transfer efficiency and bubble formation.
Q: When should the diffuser membrane be replaced?
A: Typically, the diffuser membrane lasts 5 to 8 years based on usage conditions. Replacement is advised if there is a noticeable drop in aeration efficiency, increased pressure drop, or visible membrane wear.
Q: Where is this diffuser commonly used?
A: This fine bubble diffuser is widely utilized in wastewater treatment plants, aeration tanks, and sewage water treatment facilities. It is designed for industrial, municipal, and commercial water management systems.
Q: What are the main benefits of using fine bubble diffusers in aeration tanks?
A: Fine bubble diffusers enhance oxygen transfer efficiency, improve mixing, and support effective decomposition of organic matter. They also help lower energy costs due to reduced air pressure requirements and lead to better system performance overall.
Q: How does the oxygen transfer efficiency of this diffuser compare to other types?
A: This diffuser offers an oxygen transfer efficiency (OTE) of at least 30%, which may vary depending on application parameters. The fine bubble formation ensures superior gas-liquid interface, resulting in higher aeration effectiveness compared to coarse bubble systems.
Q: What is the usual lead time for orders and can you supply in bulk?
A: Lead time generally ranges from 2 to 4 weeks. As a manufacturer, exporter, and supplier based in India, bulk supply and custom membrane sizes are available to meet specific project requirements.